Description
Festo Measured-value transducer DADE-MVC-010
- Diagnostic function: Display via LED
- Mounting position: optional
- Short circuit current rating: yes
- Reverse polarity protection: For PLC plug S1
- Repetition accuracy: Min. ± 0.1 mm
- Analogue output: 0 – 10 V To EN 61131-2
- Power supply requirements PELV
- Debounce time for inputs 3 ms
- Nominal operating voltage DC 24 V
- Power failure buffering for logic voltage 10 ms
- Residual ripple 4 Vpp
- Current consumption at nominal operating voltage 20 mA … 30 mA
- Permissible voltage fluctuations +/- 25%
- Approval RCM trademark
- KC mark KC-EMV
- CE mark (see declaration of conformity) To EU EMC Directive
- In accordance with EU RoHS Directive
- CE marking (see declaration of conformity) To UK instructions for EMC
- To UK RoHS instructions
- Corrosion resistance class CRC 1 – Low corrosion stress
- LABS (PWIS) conformity VDMA24364-B1/B2-L
- Storage temperature-20 °C … 70 °C
- Relative air humidity 95 %
- Non-condensing
- Degree of protection IP65
- IP67
- Ambient temperature 0 °C … 55 °C
- Product weight 128 g
- Linearity error in ± %FS 0.2 %
- Characteristic for outputs To EN 61131-2
- Characteristic for inputs To EN 61131-2
- Switching logic for inputs PNP (positive switching)
- Switching logic for outputs PNP (positive switching)
- Electrical connection measuring system: M12
- Socket
- 8-pin
- Electrical connection PLC: M12
- Plugs
- 8-pin
- Type of mounting: With through-hole
- Material housing: PBT-reinforced