Dwyer SERIES RSMC STABILISENSE™ CRITICAL ROOM STATUS MONITOR

View List
Category: Tags: , , Brand:

Description

Dwyer SERIES RSMC STABILISENSE™ CRITICAL ROOM STATUS MONITOR
Touchscreen LCD, Monitors Multiple Parameters

The Series RSMC StabiliSENSE™ Critical Room Status Monitor is designed for critical low differential pressure applications that require stringent pressure monitoring and alarming. It can be configured to monitor positive or negative pressure in clean rooms, hospital isolation rooms, school nurses offices, laboratories, and vivariums. The RSMC is a complete system with a touchscreen graphical user interface which enables access to pressure, humidity, temperature, air change, security, door status, calibration, and alarm setup. The graphical display color changes allow a clear determination of when the parameters are operating within the acceptable range (green), caution range (yellow), or have gone outside the acceptable operating range (red). The RSMC StabiliSENSE™ critical room status monitor comes standard with BACnet MS/TP and Modbus® RTU communications.

Features:

  • Long-term stable pressure measurements
  • User-configurable graphical interface
  • Monitors up to 3 rooms with a single
  • Displays up to 4 parameters including pressure, relative humidity, temperature, air change, and/or door status
  • Allows for flush installation in walls with space constraints with the shallow mounting depth of 1.1″ (27.5 mm)
  • Full color 4.3″ touchscreen LCD incorporates color status indication: green for good, yellow for warning, and red for alarm
  • Easy-to-clean optional brushed stainless steel bezel
  • BACnet MS/TP and Modbus® RTU communications
  • Includes RSMC, junction box, factory calibration certificate, and USB-C/USB-A flashdrive

Applications:

  • Hospital isolation rooms
  • Pharmaceutical facilities
  • Dental offices
  • School nurse offices
  • Semiconductor manufacturing facilities

Specifications:

  • Service: Air
  • Measurement Technology: Capacitance cell pressure sensor
  • Wetted Materials: Front: PMMA window with IP65 rating; Back housing: Fire-proof ABS+PC UL 94 V-0
  • Pressure Limits: 1.5 psig
  • Accuracy: ±0.25% RSS (includes non-linearity: ±0.24% BFSL, hysteresis: ±0.05% and non-repeatability: ±0.05%), or ±0.5% RSS (includes non-linearity: ±0.49% BFSL, hysteresis: ±0.05% and non-repeatability: ±0.05%)
  • Process Connection: Barbed, fits 1/8″ and 3/16″ (3 mm and 5 mm) ID rubber or vinyl tubing
  • Inputs: Two (2) user-selectable 4-20 mA, 0-5 VDC, or 0-10 VDC; USB type C used for cloning programming; One (1) digital input for door status
  • Outputs: One (1) digital output (DO) rated 5 A @ 30 VDC; One (1) 4-20 mA corresponding to pressure
  • Ambient Temperature Limits: 32 to 122°F (0 to 50°C)
  • Power Requirements: 24 VAC/VDC
  • Selectable Pressure Units: Pa, kPa, cm w.c., mm w.c., and in w.c.
  • Temperature Units: °F and °C
  • Zero and Span Adjustments: Adjustable via touchscreen
  • Power Consumption: 3.6 W @ 24 VDC
  • Electrical Connection: Removable terminal block
  • Display: 4.3″ (10.9 cm) color TFT LCD, dimmable; 480 x 272 resolution
  • Communications: Modbus® RTU, BACnet MS/TP
  • Audible Alarm: 69.1 dB 10 cm from display
  • Weight: 1.05 lb (0.476 kg).
  • Approvals: BTL, CE.

Models:

  • RSMC-A-002 Critical room status monitor, range 0-.25″ w.c., ± 0.25% accuracy
  • RSMC-A-002-SS Critical room status monitor, range 0-.25″ w.c., ± 0.25% accuracy with SS bezel
  • RSMC-A-003 Critical room status monitor, range 0-.5″ w.c., ± 0.25% accuracy
  • RSMC-A-003-SS Critical room status monitor, range 0-.5″ w.c., ± 0.25% accuracy with SS bezel
  • RSMC-A-004 Critical room status monitor, range 0-1.0″ w.c., ± 0.25% accuracy
  • RSMC-A-004-SS Critical room status monitor, range 0-1.0″ w.c., ± 0.25% accuracy with SS bezel
  • RSMC-A-013 Critical room status monitor, range -.25-0-.25″ w.c., ± 0.25% accuracy
  • RSMC-A-013-SS Critical room status monitor, range -.25-0-.25″ w.c., ± 0.25% accuracy with SS bezel
  • RSMC-A-014 Critical room status monitor, range -0.5-0-0.5″ w.c., ± 0.25% accuracy
  • RSMC-A-014-SS Critical room status monitor, range -0.5-0-0.5″ w.c., ± 0.25% accuracy with SS bezel
  • RSMC-A-015 Critical room status monitor, range -1.0-0-1.0″ w.c., ± 0.25% accuracy
  • RSMC-A-015-SS Critical room status monitor, range -1.0-0-1.0″ w.c., ± 0.25% accuracy with SS bezel
  • RSMC-B-002 Critical room status monitor, range 0-.25″ w.c., ± 0.5% accuracy
  • RSMC-B-002-SS Critical room status monitor, range 0-.25″ w.c., ± 0.5% accuracy with SS bezel
  • RSMC-B-003 Critical room status monitor, range 0-.5″ w.c., ± 0.5% accuracy
  • RSMC-B-003-SS Critical room status monitor, range 0-.5″ w.c., ± 0.5% accuracy with SS bezel
  • RSMC-B-004 Critical room status monitor, range 0-1.0″ w.c., ± 0.5% accuracy
  • RSMC-B-004-SS Critical room status monitor, range 0-1.0″ w.c., ± 0.5% accuracy with SS bezel
  • RSMC-B-013 Critical room status monitor, range -0.25-0-0.25″ w.c., ± 0.5% accuracy
  • RSMC-B-013-SS Critical room status monitor, range -0.25-0-.25″ w.c., ± 0.5% accuracy with SS bezel
  • RSMC-B-014 Critical room status monitor, range -0.5-0-0.5″ w.c., ± 0.5% accuracy
  • RSMC-B-014-SS Critical room status monitor, range -0.5-0-0.5″ w.c., ± 0.5% accuracy with SS bezel
  • RSMC-B-015 Critical room status monitor, range -1.0-0-1.0″ w.c., ± 0.5% accuracy
  • RSMC-B-015-SS Critical room status monitor, range -1.0-0-1.0″ w.c., ± 0.5% accuracy with SS bezel