Description
SERIES 1800 LOW DIFFERENTIAL PRESSURE SWITCH FOR GENERAL INDUSTRIAL SERVICE
Set Points from 0.07″ to 85″ w.c. Repetitive Accuracy within 2%
Essential for industrial environments, the Series 1800 Low Differential Pressure Switch for general industrial service combines small size and low price with 2% repeatability for all but the most demanding applications. Set point adjustment inside the mounting stud permits mounting the switch on one side of a wall or panel with adjustment easily accessible on the opposite side. UL and CSA listed, and FM approved.
CAUTION: FOR USE ONLY WITH AIR OR COMPATIBLE GASES.
Please see Series AT-1800 for ATEX approved.
Features:
- Compact size and repeatability provide a high-value switch for many industrial applications
- Designed for panel and wall mounting to easily meet mounting requirements in most industrial settings
- Pressure ranges from 0.07 in w.c. to 85 in w.c. make this switch suitable for a wide range of applications
Applications:
- Process applications
- Mechanical equipment control
Specifications:
- Service: Air and non-combustible, compatible gases
- Wetted Materials: Consult Factory
- Temperature Limits: -30 to 180°F (-34 to 82.2°C). 1823-00, -20 to 180°F (-28.9 to 82.2°C)
- Pressure Limits: 10 psig (68.95 kPa) continuous, 25 psig (172.4 kPa) surge
- Switch Type: Single-pole double-throw (SPDT)
- Repeatability: ±2%
- Electrical Rating: 15 A @ 120-480 VAC, 60 Hz. Resistive 1/8 HP @ 125 VAC, 1/4 HP @ 250 VAC, 60 Hz. De-rate to 10 A for operation at high cycle rates
- Electrical Connections: 3 screw type, common, normally open and normally closed
- Process Connections: 1/8″ female NPT
- Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations
- Set Point Adjustment: Screw type inside mounting spud
- Weight: 1 lb, 5 oz (595 g)
- Agency Approvals: CE, CSA, FM, UL
- NOTE: Optional (-EXPL) Explosion-proof Enclosure does not possess any agency approvals
Models:
1823-0 | Differential pressure switch, range 0.15-.5″ w.c., approx. deadband @ min. set point 0.06, approx. deadband @ max. set point 0.06. |
1823-00 | Differential pressure switch, range 0.07-0.22″ w.c., approx. deadband @ min. set point 0.05, approx. deadband @ max. set point 0.05. |
1823-1 | Differential pressure switch, range 0.3-1.0″ w.c., approx. deadband @ min. set point 0.08, approx. deadband @ max. set point 0.08. |
1823-10 | Differential pressure switch, range 2.0-10″ w.c., approx. deadband @ min. set point 0.18, approx. deadband @ max. set point 0.45. |
1823-2 | Differential pressure switch, range 0.5-2.0″ w.c., approx. deadband @ min. set point 0.10, approx. deadband @ max. set point 0.12. |
1823-20 | Differential pressure switch, range 3-22″ w.c., approx. deadband @ min. set point 0.35, approx. deadband @ max. set point 0.70. |
1823-40 | Differential pressure switch, range 5-44″ w.c., approx. deadband @ min. set point 0.56, approx. deadband @ max. set point 1.10. |
1823-5 | Differential pressure switch, range 1.5-5.0″ w.c., approx. deadband @ min. set point 0.14, approx. deadband @ max. set point 0.28. |
1823-80 | Differential pressure switch, range 9-85″ w.c., approx. deadband @ min. set point 1.30, approx. deadband @ max. set point 3.0. |