Festo Solenoid Valve VSNC-FC-M52-MD-G14-F8-182

  • Valve function: 5/2 double solenoid 5/2-way or 3/2-way, convertible 5/3-way, pressurised 5/3 exhausted 5/3 closed
  • Type of actuation: Electric
  • Construction width: 32 mm
  • Standard nominal flow rate: 800 l/min … 1350 l/min
  • pneumatic working port: NAMUR port pattern
  • Operating voltage: 110V AC 120V AC 12V DC 230V AC 240V AC 24V AC 24V DC 48V AC 48V DC Via solenoid coil, must be ordered separately
  • Operating pressure: 0.15 MPa … 1 MPa
  • Operating pressure: 1.5 bar … 10 bar
  • Design: Piston gate valve Poppet seat
  • Type of reset: Mechanical spring
  • Approval: c UL us – Recognized (OL)
  • CE mark (see declaration of conformity): To EU Explosion Protection Directive (ATEX) To EU Low Voltage Directive
  • Explosion protection certification outside the EU: Class I, Div. 1 (US) Class I, Div. 2 (US) Class II, Div. 1 (US) Class II, Div. 2 (US) Class III, Div. 1 (US) Class III, Div. 2 (US) EPL Da (IECEx) EPL Db (IEC-EX) EPL Db (KR) EPL Dc (KR) EPL Ga (IEC-EX) EPL Ga (KR) EPL Gb (IECEx) EPL Gb (KR) EPL Gc (KR)
  • Certificate issuing authority: DNVGL-TAA000011J
  • ATEX category gas: II 2G II 3G
  • ATEX category dust: II 2D II 3D
  • Explosion ignition protection type for gas: AEx m II T4 Ex db IIC T4 Gb Ex db IIC T5 Gb Ex ia IIC T6 Ga Ex ia IIC T6…T5 Ga Ex mb IIC T6 Ex nA IIC T5 X Gc
  • Explosion ignition protection type for dust: Ex ia IIIB T135°C Da Ex mb tb IIIC T80°C Ex t IIIC T80°C Db Ex tb IIIC T100°C Db Ex tb IIIC T135°C Db Ex tc IIIC T95°C X Dc
  • Explosion ambient temperature: -20°C <= Ta <= +50°C -20°C <= Ta <= +60°C -40°C <= Ta <= +50°C -40°C <= Ta <= +65°C -65°C <= Ta <= +40°C -65°C <= Ta <= +55°C
  • Degree of protection: IP65 IP66 IP67 With plug socket To IEC 60529
  • Exhaust-air function: With flow control option
  • Sealing principle: Soft
  • Mounting position: optional
  • Conforms to standard: VDI/VDE 3845 (NAMUR)
  • Manual override: Detenting None Non-detenting Covered
  • Type of piloting: Pilot actuated
  • Pilot air supply: Internal
  • Flow direction: Non-reversible
  • Symbol: 00991005 00991018 00991021 00991080 00991082 00991083 00991728 00991831 00991953 00995701
  • lap: Positive overlap Underlap
  • Signal status display: With accessories
  • b value: 0.4 … 0.5
  • C value: 2.1 l/sbar … 5.6 l/sbar
  • Standard nominal flow rate, exhaust return 4->3110 l/min
  • Switching time off: 6 ms … 120 ms
  • Switching time on: 4 ms … 35 ms
  • Switching time reversal: 2 ms … 55 ms
  • Duty cycle: 100%
  • Characteristic coil data: 110/120 V AC: 50/60 Hz, pick-up power 2.7 VA, holding power 1.9 VA 110/120 V AC: 50/60 Hz, pick-up power 4.4 VA, holding power 3.3 VA 110/120 V AC: 50/60 Hz, pick-up power 5.2 VA, holding power 3.1 VA 110/120 V AC: 50/60 Hz, pick-up power 6.9 VA, holding power 3.1 VA 110 V AC: 50/60 Hz, pick-up power 7.7 VA, holding power 3.8 VA 120 V AC: 60 Hz, pick-up power 10.0 VA, holding power 6.8 VA 12 V DC: 2.8 W 12 V DC: 3.4 W 230/240 V AC: 50/60 Hz, pick-up power 3.9 VA, holding power 2.8 VA 230/240 V AC: 50/60 Hz, pick-up power 5.8 VA, holding power 4.6 VA 230 V AC: 50/60 Hz, pick-up power 10.0 VA, holding power 6.0 VA 230 V AC: 50/60 Hz, pick-up power 11.5 VA, holding power 8.0 VA 230 V AC: 50/60 Hz, pick-up power 6.2 VA, holding power 3.7 VA 230 V AC: 50/60 Hz, pick-up power 6.9 VA, holding power 4.1 VA 24 V DC: 0.8 W 24 V DC: 2.1 W 24 V DC: 2.7 W 24 V DC: 3.3 W 24 V DC: 4.6 W 24 V AC: 50/60 Hz, pick-up power 2.5 VA, holding power 1.7 VA 24 V AC: 50/60 Hz, pick-up power 3.9 VA, holding power 2.6 VA 24 V DC: 0.7 W 24 V DC: 1.2 W 24 V DC: 2.6 W 48 V AC: 50/60 Hz, pick-up power 2.5 VA, holding power 1.7 VA 48 V AC: 50/60 Hz, pick-up power 3.9 VA, holding power 2.7 VA 48 V DC: 2.8 W 48 V DC: 3.4 W See solenoid coil, to be ordered separately
  • Permissible voltage fluctuations: +/- 10 %
  • Explosion protection: Class I, Div. 1 (US) Class I, Div. 2 (US) Class II, Div. 1 (US) Class II, Div. 2 (US) Class III, Div. 1 (US) Class III, Div. 2 (US) The information in the certificate must be observed! Zone 0 (IEC-EX) Zone 0 (KR) Zone 1 (ATEX) Zone 1 (IEC-EX) Zone 1 (KR) Zone 2 (ATEX) Zone 2 (KR) Zone 20 (IEC-EX) Zone 21 (ATEX) Zone 21 (IEC-EX) Zone 21 (KR) Zone 22 (ATEX) Zone 22 (KR)
  • Operating medium: Compressed air to ISO 8573-1:2010 [7:4:4]
  • Note on operating and pilot medium: Lubricated operation possible (in which case lubricated operation will always be required)
  • Corrosion resistance class CR: C2 – Moderate corrosion stress
  • LABS (PWIS) conformity: VDMA24364-B2-L
  • Media temperature: -20 °C … 60 °C
  • Ambient temperature: -20 °C … 60 °C
  • Product weight: 335 g … 685 g
  • Electrical connection: 3-pin Type A Type B Cable connector M20x1.5 M12x1, A-coded to EN 61076-2-101 Plugs To EN 175301-803 To industry standard (11 mm)
  • Type of mounting: With through-hole
  • Breather connection: Not ducted
  • Pneumatic connection, port 1: G1/4 1/4 NPT QS-6 QS-8 QS-10 QS-1/4 QS-5/16 QS-3/8
  • Pneumatic connection, port 2: NAMUR port pattern
  • Pneumatic connection, port 3: G1/4 1/4 NPT QS-6 QS-8 QS-10 QS-1/4 QS-5/16 QS-3/8
  • Pneumatic connection, port 2: NAMUR port pattern
  • Pneumatic connection, port 3: G1/4 1/4 NPT QS-6 QS-8 QS-10 QS-1/4 QS-5/16 QS-3/8
  • Pneumatic connection, port 4: NAMUR port pattern
  • Pneumatic connection, port 5: G1/4 1/4 NPT QS-6 QS-8 QS-10 QS-5/16 QS-1/4 QS-3/8
  • Note on materials: RoHS-compliant
  • Material seals: NBR
  • Material housing: Wrought aluminium alloy
  • Material screws: Galvanised steel