1-20KVA PL3 Series High Frequency Online UPS

View List
Category: Tag: Brand:

Description

1-20KVA PL3 Series High Frequency Online UPS

1KVA/2KVA/3KVA/6KVA/10KVA/15KVA/20KVA module, 208/220/230/240 VAC, 1:1

PL3 series power supply adopts online double conversion design and digital control technology and it features high input and output power factor, self-adaptive output frequency according to input frequency, intelligent battery management and excellent network management.

Features:

  • True online double-conversion technology
  • Wide input voltage range and stable power supply
  • Extended battery lifetime
  • DSP based technology
  • Advanced PF C technology, input PF>99%
  • Cold start
  • Automatic battery charging on/off mode
  • Lighting and surge protection
  • LCD/LED display
  • Support generator connection
  • Smart slot for mission critical applications

Applications:

  • Data center
  • Network
  • Servers
  • Workstations
  • Control systems
  • Communication systems,
  • Office
  • Personal computers

Technical Data:

1-3KVA PL3 Series UPS:

 

MODEL
(Low voltage version)
PL3 1KS PL3 1KL PL3 2KS PL3 2KL PL3 3KS PL3 3KL
Capacity 1kVA/1kW 1kVA/1kW 2kVA/2kW 2kVA/2kW 3kVA/3kW 3kVA/3kW
Phase 1 Phase in/1 Phase out
INPUT
Nominal Voltage 100/110/115/120/127VAC (L-N Voltage), L+N+PE
Input Voltage Range 85~155VAC (L-N Voltage)@100%load; 85~55VAC, linearly derating from 100% to 50% load
Input Frequency Range 50/60±6Hz
Input Power Factor >0.99
Input Current Distortion (THDi) <4%
Bypass Voltage Range -40%~20% of nominal voltage, adjustable
OUTPUT
Nominal Voltage 100/110/115/120/127VAC (L-N Voltage), L+N+PE
Voltage Regulation ± 1 %
Nominal Frequency 50/60Hz, adjustable
Output Frequency Line Mode:50/60±1/2/3/4/5/6Hz , adjustable  ; Battery Mode: 50/60±0.001 Hz
Output Power Factor 1
Output Voltage Distortion   (THDu) ≤3%@linear load; ≤5%@non-linear load
Transfer Time
Line mode to Battery mode, 0ms; Inverter to Bypass, 4ms (Synchronized);
Bypass to Inverter, 4ms(Synchronized); ECO to Battery Mode, 6ms (Typical Time)
Crest Ratio 3:1
Overload Capacity
 (Line Mode)
10 min @ 102%~110% load;
1 min @ 110%~130% load;
10s @130%~150% load;
200 ms @ >150% load
Overload Capacity               (Battery Mode)
1 min @ 102%~110% load;
10s @ 110%~130% load;
3s @130%~150% load;
200 ms @ >150% load
Overload Capacity                (Bypass Mode) Depending the input breaker (20A) Depending the input breaker (40A)
Output Short Circuit Protection Line Mode: Current limitation; Battery Mode: Current limitation; Bypas Mode: Breaker
BATTERY
Battery Type Sealed Lead Acid Maintanance Free (VRLA)
Nominal Voltage 24VDC 36VDC 48VDC 72VDC 72VDC 96VDC
Charging Voltage Floating Charge, 2.25V/cell; Boost Charge, 2.35V/cell
Battery Number&Capacity 2 pcs, 12V/9Ah External 4 pcs, 12V/9Ah External 8 pcs, 12V/9Ah External
Charging Current 1A 1~12A, adjustable 1A 1~12A, adjustable 1A 1~12A, adjustable
Charging Mode Two Satges (CC/Floating) or Three Stages (CC/CV/Floating, settable)
Typical Recharge Time
9 hours recharge
to 90%
Depending on the
 capacity of
external batteries
9 hours recharge
to 90%
Depending on the
 capacity of
external batteries
9 hours recharge
to 90%
Depending on the
 capacity of
external batteries
Battery Protection
Battery Leakage<500µA,Over Voltage Protection,Under Voltage Protection,Over Current Protection;
Battery Deep Discharge Protection
EFFICIENCY
Line Mode 93.5% (Max) 93.5% (Max)
Battery Mode 89.5% (Max) 90.5% (Max) 92.5% (Max) 93.5% (Max) 92.5% (Max) 93.5% (Max)
ECO Mode 98%
INDICATORS
LCD Panel UPS status, Battery Level, Load Level, Input/Outpt/Battery Voltage, Fault&Alarm Code
Audible Alarm Utility Failure, Battery Voltage Low, Overload, System Fault
MANAGEMENT
Interface RS232, USB, EPO Port, SNMP Card (Optional), Relay Card (Optional)
ENVIRONMENT
Operating Temperature 0~40
Operating Humidity 0~95% RH, non-condensing
Storage Temperature -15~60℃ (Battery: 0-40℃)
Altitude <1000m, derating 1% per 100m from 1000~2000m
Noise (1Meter Away) <50dB
PHYSICAL
Dimension
(W*D*H, unit:mm)
145*405*224 190×418*370
Net Weight (kg) 10.7 5.7 19.2 8.6 24 8.8
Color Black ( RAL9004)
STANDARDS
Safety IEC 62040-1:2017
EMC IEC 62040-2:2018
Performance IEC 62040-3:2011
Battery IEC 60896-22:2004

6-20KVA PL3 Series UPS:

MODEL PL3 6KS PL3 6KL PL3 10KS PL3 10KL PL3 15KS PL3 15KL PL3 20KS PL3 20KL
Capacity 6kVA/6kW 6kVA/6kW 10kVA/10kW 10kVA/10kW 15kVA/15kW 15kVA/15kW 15kVA/15kW 20kVA/20kW
Phase 1 Phase in/1 Phase out
INPUT
Nominal Voltage 208/220/230/240VAC (L-N Voltage), L+N+PE
Input Voltage Range 176~300VAC (L-N voltage)@100%load; 176~110VAC, linearly derating from 100% to 50% load
Input Frequency Range 50/60±6Hz
Input Power Factor >0.99
Input Current Distortion (THDi) <5%
Bypass Voltage Range -40%~20% of nominal voltage, adjustable
OUTPUT
Nominal Votage 208/220/230/240VAC, L+N+PE
Voltage Regulation ± 1 %
Nominal Frequency 50/60Hz, adjustable
Output Frequency Line Mode:50/60±1/2/3/4/5/6Hz , adjustable ; Battery Mode: 50/60±0.001 Hz
Output Power Factor 1
Output Voltage Distortion (THDu) ≤2%@linear load; ≤5%@non-linear load
Transfer Time
Line mode to Battery mode, 0ms; Inverter to Bypass, 0ms (Synchronized);
Bypass to Inverter, 0ms(Synchronized); ECO to Battery Mode, 2ms (Typical Time)
Crest Ratio 3:1
Overload Capacity
 (Line Mode)
10 min @ 102%~110% load;
1 min @ 110%~130% load;
10s @130%~150% load;
200 ms @ >150% load
30 min @ 102%~110% load;
10 min @ 110%~130% load;
30s @130%~150% load;
200 ms @ >150% load
30 min @ 102%~110% load;
10 min @ 110%~130% load;
30s @130%~150% load;
500 ms @ >150% load
Overload Capacity           (Battery Mode)
10 min @ 102%~110% load;
1 min @ 110%~130% load;
10s @130%~150% load;
200 ms @ >150% load
10 min @ 102%~110% load;
1 min @ 110%~130% load;
10s @130%~150% load;
500 ms @ >150% load
Output Short Circuit Protection Line Mode: Current limitation; Battery Mode: Current limitation; Bypass Mode: Breaker
BATTERY
Battery Type Sealed Lead Acid Maintanance Free (VRLA)
Nominal Voltage 192~240VDC, adjustable
Charging Voltage Floating Charge, 2.25V/cell; Boost Charge, 2.35V/cell
Battery Number&Capacity
16 pcs,
12V/7Ah
External
16 pcs,
12V/9Ah
External
16 pcs,
12V/9Ah
External 16 pcs*2strings, 12V/9Ah External
Charging Current 1A
1~12A,
adjustable
1A
1~12A,
adjustable
1A
1~12A,
adjustable
1~2A, adjustable, default 2A
1~12A,
adjustable
Charging Mode Two Satges (CC/Floating) or Three Stages (CC/CV/Floating, settable)
Typical Recharge Time 9 hours recharge to 90% Depending on the capacity of external batteries 9 hours recharge to 90% Depending on the capacity of external batteries 9 hours recharge to 90% Depending on the capacity of external batteries 9 hours recharge to 90% Depending on the capacity of external batteries
Battery Protection
Battery Leakage<500µA, Over Voltage Protection, Under Voltage Protection,
Over Current Protection; Battery Deep Discharge Protection
EFFICIENCY
Line Mode 95.5% (Max) 94% (Max)
Battery Mode 95% (Max) 92% (Max)
ECO Mode 98.5% 98%
INDICATORS
LCD Panel UPS status, Battery Level, Load Level, Input/Outpt/Battery Voltage, Fault&Alarm Code
Audible Alarm Utility Failure, Battery Voltage Low, Overload, System Fault
MANAGEMENT
Interface RS232 ,USB, Parallel Card, EPO Port, SNMP Card (Optional), Relay Card (Optional)
ENVIRONMENT
Operating Temperature 0~40℃
Operating Humidity 0~95% RH, non-condensing
Storage Temperature -15~60℃ (Battery: 0-40℃)
Altitude <1000m, derating 1% per 100m from 1000 ~ 2000m
Noise (1Meter Away) <55dB <60dB
PHYSICAL
Dimension
(W*D*H, unit:mm)
250x523x602 190x437x322 250x523x602 190x437x322 251*635*315 215*635*722 251*635*315 215*635*722
Net Weight (kg) 68 15 75 17 87 21 122 23
Color Black ( RAL9004)
STANDARDS
Safety IEC 62040-1:2017
EMC IEC 62040-2:2018
Performance IEC 62040-3:2011
Battery IEC 60896-22:2004