Festo Valve terminal VTUG-EX

View List
Category: Tags: , , Brand:

Description

Festo Valve terminal VTUG-EX

  • Electrical control: Fieldbus I-Port IO-Link® Multi-pin plug
  • Electrical I/O system: no
  • Operating medium: Compressed air to ISO 8573-1:2010 [7:4:4]
  • Pilot medium: Compressed air to ISO 8573-1:2010 [7:4:4]
  • Note on operating and pilot medium: Lubricated operation possible (in which case lubricated operation will always be required)
  • Media temperature: -5 °C … 60 °C
  • Ambient temperature: -5 °C … 60 °C
  • Storage temperature: -10 °C … 60 °C
  • Degree of protection: IP20 IP65
  • Corrosion resistance class CR: C2 – Moderate corrosion stress
  • Vibration resistance: Transport application test with severity level 2 to FN 942017-4 and EN 60068-2-6
  • Shock resistance: Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27
  • Operating pressure: -0.09 MPa … 1 MPa
  • Operating pressure: -0.9 bar … 10 bar
  • Pilot pressure: 0.15 MPa … 0.8 MPa
  • Pilot pressure: 1.5 bar … 8 bar
  • Operating pressure for valve terminal with internal pilot air supply: 1.5 bar … 8 bar
  • LABS (PWIS) conformity: VDMA24364-B2-L
  • CE mark (see declaration of conformity): To EU EMC Directive To EU Explosion Protection Directive (ATEX) In accordance with EU RoHS Directive
  • CE marking (see declaration of conformity): To UK instructions for EMC To UK EX instructions To UK RoHS instructions
  • Approval: RCM trademark c UL us – Recognized (OL)
  • Explosion protection: Class I, Div. 2 (CA) Class I, Div. 2 (US) Class II, Div. 2 (CA) Class II, Div. 2 (US) Zone 2 (ATEX) Zone 2 (CA) Zone 2 (CN) Zone 2 (IEC-EX) Zone 2 (US) Zone 22 (ATEX) Zone 22 (CA) Zone 22 (CN) Zone 22 (IEC-EX) Zone 22 (US)
  • ATEX category gas: II 3G
  • ATEX category dust: II 3D
  • Explosion protection certification outside the EU: Class I, Div. 2 (CA) Class I, Div. 2 (US) Class II, Division 2 (CA) Class II, Div. 2 (US) Class III (CA) Class III (US) EPL Dc (CA) EPL Dc (CN) EPL Dc (IECEx) EPL Dc (US) EPL Gc (CA) EPL Gc (CN) EPL Gc (IECEx) EPL Gc (US)
  • Explosion ignition protection type for gas: Class I, Zone 2, AEx ec IIC Gc (US) Ex ec IIC Gc (CA) Ex ec IIC T4 Gc
  • Explosion ignition protection type for dust: Class II, Zone 22, AEx tc IIIC T135 Dc (US) Ex tc IIIC T135 Dc (CA) Ex tc IIIC T135°C Dc
  • Explosion ambient temperature: -5°C <= Ta <= +50°C -5°C <= Ta <= +60°C
  • Certificate issuing authority: GYJ19.1188X IBExU16ATEXB021 X IECEx IBE 17.0003 X IECEx IBE 19.0018 X UL E198674 UL MH19482
  • Note on materials: RoHS-compliant
  • Material seals: HNBR NBR
  • Valve terminal structure: Fixed grid
  • Max. number of valve positions: 24
  • Max. number of pressure zones: 13
  • Type of actuation: Electric
  • Valve function: 2×3/2-way, monostable, closed 2×3/2-way, open, monostable 2×3/2-way, open/closed, monostable 3/2-way, closed, monostable 3/2 open, single solenoid 5/2 double solenoid 5/2-way, monostable 5/3-way, pressurised 5/3 exhausted 5/3 closed
  • Design: Piston gate valve
  • Sealing principle: Soft
  • Type of piloting: Pilot actuated
  • Valve size: 18 mm
  • Pilot air supply: External Internal
  • Max. standard nominal flow rate: 330 l/min at 10 mm 630 l/min at 14 mm 1200 l/min at 18 mm
  • Standard nominal flow rate: 130 l/min … 1150 l/min
  • Suitability for vacuum: yes
  • Exhaust-air function: With flow control option
  • pneumatic working port: M5 M7 G1/8 G1/4 QS-3 QS-4 QS-6 QS-8 QS-10 QS-5/32 QS-1/8 QS-3/16 QS-1/4 QS-5/16 QS-3/8
  • Pneumatic connection, port 1: G1/8 G1/4 G3/8 QS-3 QS-4 QS-6 QS-8 QS-10 QS-12 QS-16 QS-1/4 QS-5/16 QS-3/8 QS-1/2
  • Pilot air port 12/14: G1/8
  • Signal status display: LED
  • Nominal operating voltage DC: 24 V
  • Permissible voltage fluctuations: +/- 10 % +/- 25%
  • Nominal pick-up current per solenoid coil: 47 mA up to 20 ms
  • Nominal current with current reduction: 15.5 mA after 20 ms