Everexceed UXcelUltra Series Redundancy Charger
The EverExceed uXcelUltra redundancy charger (DC UPS) is a new type charger for battery. This charging system is made by two independent charging loop in parallel which can carry out the redundancy charge function.
This system is controlled by digital intelligence with multi charging mode, simple operation and reliability. There is no phase sequence requirement. The transformer is made by high strength paint copper and it can achieve H grade high temperature resistance and isolation. The power units are made by aluminum profile and high-power disc type thyristor units with high performance and reliability.
Available in single and three phase up to 220kW and using ultra rugged phase controlled technologies, this series is ideal for all industrial applications including substation battery systems and DC UPS.
Specifications:
Nominal Voltage | 12V | 24V | 48V | 110V | 220V | 400V |
Nominal current | 25-1500A | 25-1500A | 25-1500A | 16-1500A | 16-1500A | 16-1000A |
Input supply | Single phase 120V/220V/230V/240V,three phase 208V/380V/400V/415V/480V | |||||
Input voltage/Frequency tolerance | ± 10%, 50/60Hz ± 5% | |||||
Output voltage | 1.8-18V | 3.6-36V | 7.2-72V | 16.5-165V | 33-330V | 60-600V |
Voltage ripple | <2% specified full load and without battery connected | |||||
Static voltage regulation | ± 1% for 0-100% load variation, ± 10% AC input voltage variation and 5% AC input frequency variation | |||||
Dynamic voltage | 5% for load variation of 10% to 100% to 10% | |||||
Current regulation | 1% | |||||
Protection | Input circuit breaker, Charger output fuse/Circuit breaker*, Charger current limit, Dual battery limit, AC surge supression*, Short circuit protection, Reverse battery polarity protection, Phase lost protection* | |||||
Alarms | Charger Fail, DC High, Under/Over Voltage Trip, Earth Fault*, Low Electrolyte, Battery Disconnected*, Battery Over Temperature*, Blown Fuse*, Common Alarm Relay, Common Alarm Buzzer (All alarms are user programmable) | |||||
Metering | Charger Voltage, Charger Current, Load Voltage, Load Current, Battery Temperature*, Battery Capacity Ratio (Meter accuracy 1%) | |||||
Options | DC Voltage Regulator, TCP/IP adaptor, Triphase control and shot, Cabinet lamp Temperature and humidity controller, DC distribution board | |||||
Physical | Well mount on free standing powder coated metal cabinet (Dimensions depend on charger output rating and associated battery requirements) | |||||
Environmental | -10 to 50⁰C, up to 95% humidity | |||||
Operating attitude (m) | 3000 (without dreating) | |||||
Communication Interface | RS232/RS485 Modbus, TCP/IP Ethernet (optional) | |||||
DC Meter Disply (Optional) | For display the voltage and current of charger on the panel | |||||
MTBF/MTTR | 100000 hours/ 4hours | |||||
Efficiency | 80-93% depending on nominal voltage and power rating | |||||
Temperature compensation | Programmable 3-6 mV/Cell/⁰C | |||||
Audible noise | <60 dB | |||||
Limp home feature | Continuous operation in the event of control failure | |||||
Revert to factory settings | Reinstates all original factory settings | |||||
System | SCR full-bridge, Intelligence charging management, fast acting fuse |