Everexceed UXcelUltra Series Redundancy Charger

Posted on
Everexceed UXcelUltra Series Redundancy Charger

Everexceed UXcelUltra Series Redundancy Charger

The EverExceed uXcelUltra redundancy charger (DC UPS) is a new type charger for battery. This charging system is made by two independent charging loop in parallel which can carry out the redundancy charge function.

This system is controlled by digital intelligence with multi charging mode, simple operation and reliability. There is no phase sequence requirement. The transformer is made by high strength paint copper and it can achieve H grade high temperature resistance and isolation. The power units are made by aluminum profile and high-power disc type thyristor units with high performance and reliability.

Available in single and three phase up to 220kW and using ultra rugged phase controlled technologies, this series is ideal for all industrial applications including substation battery systems and DC UPS.

Specifications:

Nominal Voltage12V24V48V110V220V400V
Nominal current25-1500A25-1500A25-1500A16-1500A16-1500A16-1000A
Input supplySingle phase 120V/220V/230V/240V,three phase 208V/380V/400V/415V/480V
Input voltage/Frequency tolerance± 10%, 50/60Hz ± 5%
Output voltage1.8-18V3.6-36V7.2-72V16.5-165V33-330V60-600V
Voltage ripple<2% specified full load and without battery connected
Static voltage regulation± 1% for 0-100% load variation, ± 10% AC input voltage variation and 5% AC input frequency variation
Dynamic voltage5% for load variation of 10% to 100% to 10%
Current regulation 1%
ProtectionInput circuit breaker, Charger output fuse/Circuit breaker*, Charger current limit, Dual battery limit, AC surge supression*, Short circuit protection, Reverse battery polarity protection, Phase lost protection*
AlarmsCharger Fail, DC High, Under/Over Voltage Trip, Earth Fault*, Low Electrolyte, Battery Disconnected*, Battery Over Temperature*, Blown Fuse*, Common Alarm Relay, Common Alarm Buzzer (All alarms are user programmable) 
MeteringCharger Voltage, Charger Current, Load Voltage, Load Current, Battery Temperature*, Battery Capacity Ratio (Meter accuracy 1%)
OptionsDC Voltage Regulator, TCP/IP adaptor, Triphase control and shot, Cabinet lamp Temperature and humidity controller, DC distribution board
PhysicalWell mount on free standing powder coated metal cabinet (Dimensions depend on charger output rating and associated battery requirements)
Environmental-10 to 50⁰C, up to 95% humidity
Operating attitude (m)3000 (without dreating)
Communication InterfaceRS232/RS485 Modbus, TCP/IP Ethernet (optional)
DC Meter Disply (Optional)For display the voltage and current of charger on the panel
MTBF/MTTR100000 hours/ 4hours
Efficiency80-93% depending on nominal voltage and power rating
Temperature compensationProgrammable 3-6 mV/Cell/⁰C
Audible noise<60 dB
Limp home featureContinuous operation in the event of control failure
Revert to factory settingsReinstates all original factory settings
SystemSCR full-bridge, Intelligence charging management, fast acting fuse