RAVEN-EYE® ATEX Technical Specifications
The RAVEN-EYE® ATEX is a universal non-contact level/velocity flow sensor that can be connected to the RTQ-2000 or the IFQ MONITOR. The use of a barrier box between the IFQ MONITORTM and the RAVEN-EYE® ATEX is mandatory to comply with electrical parameters.
Velocity Measurement
- Method Radar
- Range ±0,15 to ±9 m/s (bi-directional)
- Accuracy ±0,5%, + zero stability
- Zero Stability ±0,02 m/s
- Resolution 0,001 m/s
Optional Combined Level Measurement (Radar)
- Method Radar
- Range 0,01 to 15 m
- Accuracy ±2 mm of reading
- Resolution 1 mm
- Mounting Separate
- Approval CE, ATEX (II 1G, 1/2G, 2G Ex ia IIC T6 Ga, Ga/Gb, Gb) – barrier box needed
Optional Separate Level Measurement
- Method: Any 4-20 mA loop powered sensor fulfilling the necessary ATEX requirements
Flow Measurement
- Method Conversion from surface velocity measurement to average velocity based on patent pending selflearning model using velocity distribution measurements.
- Conversion of water level and pipe size to fluid area. Multiplication of fluid area by average velocity to obtain the flow rate.
- Conversion Accuracy ±5% of reading Assumes pipe is 0 to 90% full
Communication
- RS-485 communications port with Modbus ASCII slave communication protocol
Power Supply
- Supplied by IFQ MONITORTM for ATEX sensors via ATEX barrier or RTQ-2000
Safety parameters
- Power supply RS485
- Ui = 8,7 V Ui = 8,7 V Uo = 5,88 V
- Ii = 0,73 A Li = 0,73 A Lo = 0,24 A
- Pi = 1,6 W Pi = 1,6 W Po = 35,21 mW
- Ci = 10,6 µF Ci = 0 µF Co = 24, 5 µF
- Li = 4,7 µH Li = 0 µH Lo = 30 µH
- Lo/Ro = 3,99 µH/Ohm
Internal Temperature Measurement
- Method Digital sensor
- Range -40º to 80º C
Internal Humidity Measurement
- Method Digital sensor
- Range 0 to 100 %
Internal Pressure Measurement
- Method Digital sensor
- Range 0 to1500 HPa
Material & Dimensions
- Enclosure Polyurethane (PU), PU ESD-dissipative paint
- Dimensions 422 mm L, 140 mm W, 183 mm H
- Weight 3,85 Kg (without the cable, level sensor and mounting accessories)
- Protection rate IP68
Environmental Conditions
- Operating temperature range -20° to 50° C
- Storage temperature range -30º to 60º C
Certifications
- CE
- ATEX ATEX Directive 94/9/EC
- EN60079-0 : 2012 + A11 : 2013 (CEI 60079-0 : 2011)
- EN60079-11 : 2012 (CEI 60079-11 : 2011)
- Marking: II 2 G Ex ib IIB T4 Gb
Sensor Cable
- Material Polyurethane jacketed
- Length Standard: 10 m
- Optional lengths on request