Dwyer Instruments in Data Centers

Posted on

Running a data center, be it in-house for your computer systems and servers, or big third-party, offsite data centers for cloud data, requires a lot of environmental monitoring to ensure that everything runs smoothly, safely and efficiently. Properly monitored data center results also in longer life of your equipment and also avoids expensive downtime and outages.

Dwyer Instruments has the full range of environmental monitoring products, for humidity, temperature, air velocity sensors and for differential pressure measurement inside data centers.

DWYER SERIES RHP Humidity – Temperature Transmitters

Series RHP Temperature and Humidity Transmitter

Humidity can break down critical components that is why it is crucial to monitor precise humidity 24/7. The SERIES RHP Humidity – Temperature transmitter will do just that. The Series RHP Temperature and Humidity Transmitter combine the voltage or current humidity transmitter output with a passive temperature thermistor or RTD output. Featuring polymer capacitance humidity sensors, models are available in 2%, 3% or 5% accuracies. Duct mounted transmitters are available with an optional two-line alpha numeric LCD display.

DWYER SERIES TE-E/N Wall-mount Temperature Sensors

Series TE-E/N Wall Mount Temperature Sensor

The hardware and equipment inside data centers work non-stop and are prone to overheating. The Series TE-E/N Wall Mount Temperature Sensor is an ideal sensor for data centers. It provides a low cost temperature input for any building management system. With large vents in the housing for proper air flow, the sensor accurately measures the ambient temperature in the room. Multiple mounting holes on the wall plate allow for mounting to numerous surfaces.

DWYER SERIES AVUL and AVLV Air Velocity Transmitter

Series AVUL Air Velocity Transmitters

The Series AVUL and AVLV air velocity transmitters are a great choice for monitoring air velocity or volumetric flow in a building duct. These units provide a linear velocity output signal that can be paired with a building management system. In particular, the lower ranges of the AVLV high accuracy units are ideal for applications in quality intensive environments like data centers.

DWYER Series MSX and MSX Pro Magnesense Differential Pressure Transmitters

Series MSX Magnesense® Differential Pressure Transmitter 

The Dwyer® Series MSX and MSX Pro Magnesense® differential pressure transmitters have the high accuracy pressure measurement required for exacting control. Standard square root capability converts a velocity pressure into a velocity flow or volumetric flow eliminating the need for additional air flow instrumentation and simplifying programming at the BMS. Additionally, the MSX or MSX Pro can be used to notify both a local alarm and control system via dual voltage and current output signals. Within data centers, these transmitters are used for controlling VFD driven air supply in the HVAC system and monitoring pressure drop across filters to maintain clean air cooling the data center racks.

For more information about the products mentioned above or any other Dwyer products, our Dwyer Engineers will be glad to assist you. Contact us at sales @ braamd.com